Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T01CM01694
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/18/2001 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
10/10/2001 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) OSB SHEAR PANELS MUST BE BLOCKED AND NAILED AT 8' ELEVATION SEAM 2) NO CITY OF TUCSON APPROVED TRUSS PLANS/DRAWINGS ON SITE 3) NO TURTHER INSPETIONS WILL BE MADE UNTIL NORTH PROPERTY PINS ARE ESTABLISHED AND SET BACKS ARE PER PLAN 4) PROVIDE CITY OF TUCSON APPROVED DETAIL OF BRICK WALL TO WOOD FRAME CONNECTION ON SOUTH WALL 5) PROVIDE EPOXY BOLT SPECIAL INSPECTION CERTIFICATE 6) TRUSSES ON SOUTH BRICK WALL NOT BEARING ON PLATE 7) WOOD LINTLES NOT ALLOWED ON MASONARY |