Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/14/2001 | ROOF NAILING | Approved | IVRS - Inspection 0000* | |
06/07/2001 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) AT FRONT GABLE USE COLLAR TIES IN LOWER 2/3D OF GABLE 2) SHEAR PANELS NOT NAILED TO ROOF DECK SEE D-1 PAGE 3) NAIL ALL PERIMETERS AT BLOCKS PER PLAN 4) REMOVE PIECE OF 3/8" ROOF SHEET AT FRONT 5) NAIL GABLE NAILED TO END TRUSS 6) MISSING PLATES FOR GABLE |