Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
| Date |
Description |
Inspector |
Results |
Comments |
| 06/04/2001 |
PLUMBING - PROGRESS |
|
Approved |
IVRS - Inspection 0000* |
| 05/18/2001 |
PLUMBING - PROGRESS |
|
Partial Approval |
IVRS - Inspection 0000* |
| 05/16/2001 |
PLUMBING - PROGRESS |
|
Denied |
IVRS - Inspection 0999* 1) SUPPORT VERTICAL VENT RISERS 2) ABS MUST BE SUPPORTED 4' MAX HORIZONTALLY 3) GREASE TRAP IS 4" DRAIN IS 3" CONSIDERED AN OBSTRUCTION 4) 3 COMP SINK NOT INSTALLED PER PLAN 5) 12" MAX ON T AND P FLEX CONNECTOR 6) SUPPORT ALL COPPER 7) WHEN CONNECTING N/H TO PLASTIC USE A MISSION COUPLING 8) STRAP HORIZONTAL VENT ABOVE BATHROOM |
| 05/15/2001 |
PLUMBING - PROGRESS |
|
Denied |
IVRS - Inspection 0999*LOCKED NO ACCESS |