Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM01615

Parcel: 141147670

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/18/2001 FRAMING Approved IVRS - Inspection 0000*
05/15/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) MOVE PEX OFF OF FURNACE FLUE 2) SECURE GAS PIPE BRACKET IN GARAGE ABOVE FURNACE 3) MUCH WORK NEEDED AT REAR LEFT GARAGE CORNER-SLAB TO 2ND FLOOR 4) STRAP TOP PLATES IN GARAGE AT A/C LINES 5) SHIM HEADERS WHERE NEEDED 6) FINISH FRAMING OVER FRONT WINDOWS 7) CORRECT CUT STUD AT STOVE 8) GROUT TUB DRAIN BOX AND REPAIR SHEARWALL 9) NO DRAINAGE TEST
05/11/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*