Permit: T01CM01602

Parcel: 112031770


Addresses:

3301 N STEWART AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/03/2001 FRAMING Approved IVRS - Inspection 0000*
07/27/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) BLOCK (WITH 2 X LUMBER) MECHANICAL DUCT BOOTS ON 3 SIDES 2) INSTALL TOILET FLOOR FLANGE AND SECURE TO FLOOR 3) PROVIDE NAIL PROTECTION OVER ALL PLUMBING AND ELECTRICAL WITHIN 1 1/4" OF STUD SURFACE. PLUMBING NOT COMPLETE 4) PROVIDE MINIMUM PO PSI GAS PRESSURE TEST OF ALL GAS PIPES 5) PROVIDE GROUND PIG TAILS FOR ALL LIGHT SWITCHES 6) WOOD TRUSSES CANNOT BE WITHIN 2" OF MASONARY FIREPLACE 7) BEDROOM REQUIRES HARD WIRED SMOKE DETECTOR ALSO FAMILY ROOM 8) OK TO INSULATE ALL BUT REPAIR AREA