Permit: T01CM01593

Parcel: 117031650


Addresses:

827 N 10TH AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/13/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*
04/10/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*/1. WEST LAUNDRY AND BATH TUB NOT PROPERLY INSTALLED TAIL PIECES EXCEED 24" IN LENGTH. LAUNDRY TRAP MUST BE A MINIMUM OF 6" ABOVE FLOOR. 2. INCORRECT KITCHEN SINK DRAIN TAIL CONNECTOR INSTALLED. 3. BATHROOM GFCI MUST BE ON SEPARATE ELECTRIC CIRCUIT FROM ALL OTHER ROOMS. 4. BATHROOMS REQUIRE SAFETY GLAZING IN TUB WET AREA WHEN GLASS IS WITHIN 60" OF FLOOR HEIGHT. 5. WEST BATH MUST HAVE GFCI AT LAV. WITHOUT CROSSING WALK WAY. 6. LAUNDRY REQUIRES EXHAUST FAN. 7. SOUTH END BATH INADEQUATE CLEARANCE IN FRONT OF WATER CLOSET.