Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/16/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 07/19/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NOTE: OK-TO COVER EXCEPT PLUMBING WALLS |
| 06/04/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) BLOCK DUCT DEFUSER BOOTS 3 SIDES 2) ALL WIRES MUST TERMINATE IN APPROVED BOXES 3) NO ELECTRIC PLAN ON SITE 4) PROVIDE A MINIMUM 10 PSI PRESSURE TEST ON GAS LINE 5) NO MECHANICAL PLAN ON SITE 6) NAIL PROTECT ALL PLUMBING AND ELECTRIC WITHIN 1 1/4" OF WALL SURFACE 7) PORCH NOT READY-CLIP LEADGER 8) PROVIDE PLUMBING PLAN OR APPROVED PLUMBING PERMIT FOR ADDED BATH AT SOUTHEAST CORNER OF BUILDING |