Permit: T01CM01555

Parcel: 133541060

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/22/2001 FRAMING Approved IVRS - Inspection 0000*
05/21/2001 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) MOVE WIRES AWAY FROM FURNACE FLUE 2) MISSING F/BLOCKING AT LAUNDRY 3) SEAL AIR PLENUM 4) MISSING LTT 20 AT GARAGE SHEAR WALL 5) BLOCK FOR DEFFUSERS 3 SIDES 6) FURNACE FLUE AT 2ND FLOOR AGAINST COMBUSTIBLES 7) GAS GAUGE DOES NOT REGISTER PROPERLY