Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/25/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 05/23/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FHA STRAP PROTECTING REFRIGERENT LINE IS IMPOSING STRESS TO COPPER AT THIS TIME COPPER MAY NEED BRACING 2) PROVIDE FHA STRAPS WITH NAILS BOTH PLATES AT OVER KNOTCHED DOUBLE TOP PLATE FOR CONDENSATION LINES 3) BLOCK OSB AT CHIMNEY FLUE PENETRATION CHECK DRAFT STOP AT REPAIR 4) SEAL RACEWAY BEHIND ELECTRIC PANEL PROVIDE INSULATION OR MEANS OF DRAFT STOPS ABOVE PANEL AT DOUBLE TOP PLATE 5) PROVIDE A MINIMUM OF 50 PSI FOR PEX LINE |