Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/09/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000*/ NOTE: PTR LINE SHALL TERMINATE 6" MINIMUM 24" MAXIMUM FROM FINISH GRADE, PRIOR TO FINAL, ADJUST AS NEEDED |
| 07/08/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE POST TO BEAM CONNECTIONS AT INTERIOR BEARING WALLS INSTALL EXPANSION BOLTS AT THESE LOCATIONS SECURE BEAM HORIZONTALLY TO DOUBLE TOP PLATE 2) PROVIDE EXPANSION BOLTS AT EXTERIOR SHEARWALLS AS PER PLAN AND SINGLE SOLE PLATES TWO 12 INCHES FROM SPLICE REQUIRED 3) NAIL SHEAR TRANSFER AT GARAGE 8 INCH ON CENTER 4) THREE WAY SWITCH NOT INSTALLED AT FAMILY ROOM AS PER PLAN 5) INSTALL EXHAUST FAN DAMPERS 6) SECURE ROMEX CABLE HORIZONTALLY THRU OUT 7) REPLACE ROMEX CABLE AT PANEL PENETRATED BY STAPLES |