Permit: T01CM01509

Parcel: 117170110


Addresses:

135 S 6TH AV


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T01CM01509

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
07/05/2001 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*1.) DOORS LOCKED NO ACCESS REINSPECTION 7:15 GAS PRESSURE TEST OK REVIEWED REVISED APPROVED PLAN OK
07/02/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*1.) NO ACCESS TO MECHANICAL RM 2.) WHERE UNIONS ARE NECESSARY, RIGHT, LEFT NIPPLE AND COUPLING SHALL BE USED. A GROUND JOINT UNION MAY BE USED IN AN EXPOSED EXTERIOR LOCATION, IMMEDIATELY ON THE DISCHARGE SIDE OF AN APPROVED BUILDING SHUT OFF VALVE. 1211.10 94UPC 3.) ALL EXPOSED GAS PIPING SHALL BE KEPT AT LEAST 6" ABOVE GRADE OR STURCTURE 4.) VERIFY THAT ALL GAS VALVES ARE AGA OR CSA APPROVED.
06/28/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*1.) NEED TO SEE PRESSURE TEST ON ENTIRE SYSTEM 2.) BE ADVISED IT IS NOT RECOMMENDED TO TEST THRU ANSEL VALUE. 3.) MAKE SURE ALL VALUES ARE AGA,CSA, APPROVED.