Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/03/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000*/ NOTE: PROVIDE BOND TO WATER PIPE, PROVIDE REVISION FOR 0 CLEARANCE FIREPLACE |
| 08/02/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*1.) PROVIDE BOND TO GAS LINE & WATER METALLIC PIPE 2.) GROUT TUB PENETRATION TO EARTH 3.) REMOVE ROMEX @ REAR OR PROVIDE RECEP BOX POWER NOT TO BE PROVIDED TO STORAGE ADDITION.4.) PROVIDE BLOCKING AS PER PLAN @ GABLE END TRUSS BOTH SIDE AS PER DETAIL STRUCTURAL 5.)PROVIDE APPROVED REVISION FOR CHIMNEY FIREPLACE. |
| 07/31/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE 2 X 4 BLOCKING AT GABLE END DETAIL PER PLAN 2) FIREPLACE NOT ON PLANS 3) A.35'S AT GABLE END PER PLAN 4) ROMEX AT REAR 5) 6" CLEARANCE AT FIREPLACE FROM COMBUSTIBLES PER MANUFACTURERS SPECIFICATIONS 6) NON COMBUSTIBLE BOTTOM 7) FIREPLACE NOT INSTALLED AS PER MANUFACTURERS SPECIFICATIONS 8) SEVERAL INSPECTIONS HAVE BEEN MADE WITH SAME RESULTS NON COMPLIANCE WILL IMPOSE A RE-INSPECTION FEE ALL MODIFICATIONS MUST BE ADDRESSED ON PLAN TO MEET WITH AN INSPECTOR LEAVE MESSAGE |
| 07/26/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SECURE ROMEX 2) PROVIDE PROPER GRD SCREEN AT METAL BOXES 3) SUPPORT GAS LINE 4) COMBUSTIBLES AT FIREPLACE FLUE 5) GROUT TUB 6) PROVIDE BOX FOR FIXTURE AT FRONT 7) PRESSURE RELIEF AT WATER HEATER LEAKING 8) 1" CLEARANCE AT WATER HEATER FLUE VENT 9) ELECTRIC WIRE AT REAR |
| 07/24/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) REMOVE TAPE FROM SINGLE WALL FLUE VENT PIPE TO DOUBLE WALL CONNECTION AT HOT WATER HEATER 2) PROVIDE 1" CLEARANCE FROM COMBUSTIBLE MATERIAL AT HOT WATER FLUE PIPE 3) BOTTOM OF FLUE CAP NEEDS TO BE 12 INCHES ABOVE ROOF 4) COMPLETE ROMEX IN BOXES PROTECTIVE COVER IN BOX MAX 1" MINIMUM 1/4" 5) PROTECT ELECTRIC ROMEX BEHIND PANEL WITHIN 1/4" FROM EDGE 6) REMOVE SCREEN FROM COMBUSTION AIR VENTS ON FURNACE CAVITY, SEE IRC 1703.3/UMC 702.3 6) REMOVE LOW VOLT FROM HIGH VOLT LOCK BOX WITH COMBD RAM 7) TO MANY ITEMS TO LIST |
| 07/23/2001 |
FRAMING |
|
Denied |
1) PROVIDE R.A.M. 1" CLEARANCE FROM COMBSUTIBLE MATERIAL AT FIREPLACE FLUE PIPE 2) SECURE PEX THRU-OUT 3) PROVIDE APPROVED NAILS AT GIRDER AT HANGER 4) NO GAS PRESSURE TEST |
| 06/26/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FRAMING CONNOT BE APPROVED UNTIL ALL TRADES ARE COMPLETED |