Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 07/31/2001 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 07/27/2001 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) NEED TO MOVE M/C CABLE OUT OF CHANNEL 2.) MISSING PLASTER RING. 3.) NEED FHA STRAPS ON SHALLOW STUDS TO PROTECT M/C CABLE ALSO WHERE POUNCHED HOLE IS CLOSE TO EDGE. 4.) SUPPORT M/C CABLE AS PER CODE.5.) FINISH TERMNATEING. M/C CABLE TO PANEL.6.) FILL UNUSED OPENING IN PANEL.7.) LOOSE M/C FITTINGS 8.) NEED LETTER AUTURIZING USE OF M/C CABLE. |