| 03/06/2002 |
ELECTRIC - UFER |
|
Approved |
IVRS - Inspection 0000* |
| 03/05/2002 |
ELECTRIC - UFER |
|
Denied |
IVRS - Inspection 0925*1.) INSTALL A GROUNDING BUSHING AND A BONDING JUMPER @ RISER. 2.) LISTING INDICATER THAT YOU CANNOT EXCEED 110 AMPS PER BUS STAB. 3.) NEED ACCURATE CITY APPROVED. PLAN |