Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM01451
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/25/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
05/23/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) STRAP PLATES WHERE OVER DRILLED FOR ELECTRIC AND PLUMBING PEX AND CONDENSATE LINES 2) WRENCH TIGHTEN ANCHORS 3) REMOUNT ELECTRIC BOX AT KITCHEN BOTTOM PLATE 4) SHIM BLOCKS OVER FAMILY ROOM WINDOW HEADER AND ADD 2ND KING 5) NEED SIMPSON HSS STUD SHOES ON 1ST FLOOR BATH PLUMBING WALL 6) SHIM TRIMMERS 1ST FLOOR BEDROOM WINDOW 7) STRAP 2ND FLOOR TOP PLATES AT KITCHEN PLUMBING VENT MASTER BEDROOM AND AT CONDENSATE LINES |