Permit: T01CM01451

Parcel: 141113240

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM01451

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/25/2001 FRAMING Approved IVRS - Inspection 0000*
05/23/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) STRAP PLATES WHERE OVER DRILLED FOR ELECTRIC AND PLUMBING PEX AND CONDENSATE LINES 2) WRENCH TIGHTEN ANCHORS 3) REMOUNT ELECTRIC BOX AT KITCHEN BOTTOM PLATE 4) SHIM BLOCKS OVER FAMILY ROOM WINDOW HEADER AND ADD 2ND KING 5) NEED SIMPSON HSS STUD SHOES ON 1ST FLOOR BATH PLUMBING WALL 6) SHIM TRIMMERS 1ST FLOOR BEDROOM WINDOW 7) STRAP 2ND FLOOR TOP PLATES AT KITCHEN PLUMBING VENT MASTER BEDROOM AND AT CONDENSATE LINES