Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/21/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/20/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) CONDENSATION LINE HAS NEGATIVE FLOW 2) TRAP AND TRAP ARM REQUIRED TO BE SAME SIZE PER CODE 3) PROVIDE 1" CLEARANCE FOR FIREPLACE FLUE AT ROOF 4) STUCCO MESH NOT COMPLETE AT REAR |
| 06/18/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) COND LINE 2) FLEX AT EXHAUST FAN IN LAUNDRY 3) PROVIDE 1" CLEARANCE AT FIRE PLACE FLUE VENT PENETRATION AT ROOF 4) SMOKE DETECTOR AT BEDROOM REQUIRES 36" FROM MECHANICAL 5) FLEX AT EXHAUST FAN IN MASTER BATH 6) FIX TOP PLATE AT DRYER VENT 7) CHECK NAIL PROTECTION THRU OUT |