Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM01387
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/18/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
10/08/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) PROVIDE NAIL PROTECTION OVER ALL PLUMBING WITHIN 1 1/4" OF STUD ANDPLATE SURFACES 2) BACK GROUT/SEAL FLOOR PENETRATION FOR TUB 3) BATH EXHAUST MUST EXHAUST OUTSIDE 4) DUCT WORK NOT INSTALLED | |
08/14/2001 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) FRAME OK, CANNOT APPROVE UNTIL ELECTRIC PLUMBING AND MECHANICAL ARE APPROVED |