Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01CM01345

Parcel: 13307015A

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T01CM01345

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/14/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/13/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NEED VERIFICATION A35'S LEDGER TO STUDS 2) FIREBLOCKS MISSING 3) FURR DOWNS INCOMPLETE 4) PROVIDE FULL BEARING DOUBLE 2 X BATH HEADER 5) ELECTRIC INCOMPLETE AND NOT TO PLAN