Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/04/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 05/30/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) LEDGER AT ENTRY WAY PORCH MISSING A 35S 2) PROVIDE BOXES FOR ALL LIGHT FIXTURES 3) KITCHEN SINK NOT INSTALLED AS PER PLAN LOCATION 4) BEARING HEADERS NOT INSTALLED AS FOR DETAIL 1/5 SHEET 5 5) PEX LINE AT GARAGE STRESSED BY LEDGER |