Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM01318

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/14/2001 FRAMING Approved IVRS - Inspection 0000*
09/13/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) BLOCK ALL MECHANICAL VENTS 2) REMOVE SCREWS FROM INSIDE-DRYER DUCT, USE PLUMBERS TAPE 3) NEED FIRE STOP COLLAR FIREPLACE MAINTAIN 2" CLEAR TO COMBUSTIBLES 4) WATER LINE TOP PLATE WEST SHOWER PROTECT FROM SHARP METAL STUD EDGE 5) HEARTH SAFETY STRIP GOES 1/2 OUT 1/2 UNDER FIREPLACE, SEE INSTALLATION INSTRUCTIONS 6) GAS TEST OK 7) NO RISER FOR ELECTRIC PANEL