Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T01CM01318

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/31/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/28/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) ADD CROSS BRACE BETWEEN FRONT AND BACK CROSS BRACE 2) REAR TRUSS END OSB MISSING ATTACH VENT TO THE TRUSS
08/24/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*SEE LAST REJECTION.
08/21/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) DO NOT LOAD ROOF 2) NAIL AND SUPPORT FRONT FACES OF GABLES 3) INSTALL CROSS BRACING FOR TRUSSES
07/26/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) BOTTOM PLATE ATTACHMENT TO CONCRETE-OK