Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T01CM01318
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/31/2001 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
08/28/2001 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) ADD CROSS BRACE BETWEEN FRONT AND BACK CROSS BRACE 2) REAR TRUSS END OSB MISSING ATTACH VENT TO THE TRUSS | |
08/24/2001 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*SEE LAST REJECTION. | |
08/21/2001 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) DO NOT LOAD ROOF 2) NAIL AND SUPPORT FRONT FACES OF GABLES 3) INSTALL CROSS BRACING FOR TRUSSES | |
07/26/2001 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) BOTTOM PLATE ATTACHMENT TO CONCRETE-OK |