Permit: T01CM01292

Parcel: 136282300


Addresses:

7750 E LOCUST ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
06/12/2001 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
05/31/2001 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/ 1) WIRE NEAR J-BOX, NEEDS A BUSHING SHORT PIECE OF CONDUIT, BUSHING GOES ON THE END OF PIPE SHARP EDGE 2) SECURE ALL ROMEX WITH STAPLES , WITHIN 6" OF EACH BOX 3) MAKE UP ALL WIRING IN BOXES, GROUND TO GREEN SCREW EACH BOX, PIG TAIL, PIG TAIL NEUTRALS, OR INSTALL OUTLETS, LIGHTS AND SWITCHES, PROTECT ROMEX TO CEILING HEIGHT