Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/12/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000*/ 1) NEED TO MOVE AIR GRILLE OUT OF GARAGE, 1/2" X / 5/8" RATED ROCK ON LID 2) NEED SOLID CORE SELF CLOSING DOOR AT GARAGE 3) GFCI RATED OUTLETS GARAGE 4) GREEN BOARD IN SHOWER |
| 06/06/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 05/25/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0333*/ 1) WORK COVERED WITHOUT INSPECTION, MOVED SHOWER, NEW LOCATION COVERED, CONCRETED IN 2) BOTTOM PLATES INSTALLED NOT PRESSURE TREATED 3) ALL ROMEX TO BE SECURED WITH IN 6 INCHES OF EACH (BOX) OPENING 4) SOLDER JOINTS BELOW SLAB 5) WIRING RUN WITH OUT INSPECTION DRY WALLED 6) SHOWER WILL NEED INSPECTION, DRY WALL 7) SOME TYPE OF FORCED AIR GRILL IN GARGAE MUST BE PUT ON PLAN REQS. FIRE DAMPERS |
| 05/23/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NO PLANS/PERMIT ON SITE |