Permit: T01CM01280

Parcel: 110046030

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM01280

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/07/2001 FRAMING Approved IVRS - Inspection 0000*
06/05/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) WATER HEATER PLATFORM NOT LEVEL 2) #5 SHEAR WALL REQUIRES NAILS AT 3" ON CENTER 3) LAUNDRY #2 SHEAR WALL FURRED OUT-FURRING MUST BE NAILED SAME AS DRYWALL SPACING IN RAILS AND PROVIDE BLOCKING AT TOP PLATE NORTH WALL 4) 6 EACH BEARING STUDS KNOTCHED GREATER THAN 25 PERCENT-REPLACE 5) BLOCKING MISSING TOP AND BOTTOM-SECTION 8/SD3 6) "S" TRAP NOT ALLOWED AT TUB 7) DOUBLE SHEAR WALLS #2 NOT ANCHORED PER PLAN