Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/07/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/05/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) WATER HEATER PLATFORM NOT LEVEL 2) #5 SHEAR WALL REQUIRES NAILS AT 3" ON CENTER 3) LAUNDRY #2 SHEAR WALL FURRED OUT-FURRING MUST BE NAILED SAME AS DRYWALL SPACING IN RAILS AND PROVIDE BLOCKING AT TOP PLATE NORTH WALL 4) 6 EACH BEARING STUDS KNOTCHED GREATER THAN 25 PERCENT-REPLACE 5) BLOCKING MISSING TOP AND BOTTOM-SECTION 8/SD3 6) "S" TRAP NOT ALLOWED AT TUB 7) DOUBLE SHEAR WALLS #2 NOT ANCHORED PER PLAN |