Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM01280
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/07/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
06/05/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) WATER HEATER PLATFORM NOT LEVEL 2) #5 SHEAR WALL REQUIRES NAILS AT 3" ON CENTER 3) LAUNDRY #2 SHEAR WALL FURRED OUT-FURRING MUST BE NAILED SAME AS DRYWALL SPACING IN RAILS AND PROVIDE BLOCKING AT TOP PLATE NORTH WALL 4) 6 EACH BEARING STUDS KNOTCHED GREATER THAN 25 PERCENT-REPLACE 5) BLOCKING MISSING TOP AND BOTTOM-SECTION 8/SD3 6) "S" TRAP NOT ALLOWED AT TUB 7) DOUBLE SHEAR WALLS #2 NOT ANCHORED PER PLAN |