Permit: T01CM01273

Parcel: 141113110

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM01273

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/05/2001 FRAMING Approved IVRS - Inspection 0000*
06/01/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) PART OF #6 NOT DONE 2) #7 NOT DONE
05/31/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) STRAP TOP PLATES AT PEX CUT IN GARAGE 2) NO GAS PRESSURE 3) BLOCK DUCT IN DOWNSTAIRS BATH 4) STRAP CUT PLATES AT 1ST FLOOR CONDENSATE LINES 5) NEED COMBUSTIBLE CLEARANCE TO HOT WATER FLUE 2ND FLOOR 6) STRAP TOP PLATES AT VENT CUTS MASTER CLOSET AND BEDROOM AND WEST BED CLOSET 7) FIREBLOCK DUCT CHASE IN MASTER CLOSET 8) SUPPORT VENT 90 DEGREE IN MASTER BATH AND HALL BATH