Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T01CM01243

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/19/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
04/18/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/1) NEED MORE RE HEADERS AT FRONT COLUMN 2) CORRECT PATIO COLUMN AT BOTTOM
04/16/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1) STRAP NON-CABIN-TIED TOP PLATES AT FRONT ENTRY ANGLED WALLS 2) FRONT COLUMN NEEDS 2 ANCHORS PER PLATE 3) STRAP HEADER OVER FRONT WINDOW 4) ATTACH FRONT ENRY WALL TO GABLE TRUSS 5) STRAP PATIO COLUMN TO PLATES 6) CLIP/STRAP ALL REAR WINDOW HEADERS 7) MISSING STUD CLIPS AT REAR WALL 8) HAVE PLUMBER STRAP ALL BOTTOM PLATES WHERE CUT