| 04/19/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/18/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/1) NEED MORE RE HEADERS AT FRONT COLUMN 2) CORRECT PATIO COLUMN AT BOTTOM |
| 04/16/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1) STRAP NON-CABIN-TIED TOP PLATES AT FRONT ENTRY ANGLED WALLS 2) FRONT COLUMN NEEDS 2 ANCHORS PER PLATE 3) STRAP HEADER OVER FRONT WINDOW 4) ATTACH FRONT ENRY WALL TO GABLE TRUSS 5) STRAP PATIO COLUMN TO PLATES 6) CLIP/STRAP ALL REAR WINDOW HEADERS 7) MISSING STUD CLIPS AT REAR WALL 8) HAVE PLUMBER STRAP ALL BOTTOM PLATES WHERE CUT |