Permit: T01CM01210

Parcel: 13311004C

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T01CM01210

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/21/2001 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
12/18/2001 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0245*NOTES 1.) SEE LAST INSPECTION WRITE UP 2.) CHECK RECEPT SPACING ALL UNITS 3.) CANNOT INSPECT WALLS WITH DRYWALL STACKED ON BOTH SIDES
11/19/2001 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*1.) BOTTOM UNITS NORTH SIDE INSTALL FLEX CONDUITS TO WH'S & NAIL TO WALL 2.) BOTTOM EAST UNIT STAPLE ROMEX AND ISNTALL INTO BOX AT BATHROOM. 3.) MIDDLE UNITS BOTTOM SUPPORT ROMEX WITHIN 12" OF PANCAKE BOXES 4.) NAIL ALL WH FLEXS TO STUDS 5.) ALL OUTSIDE STORAGE ROOMS SUPPORT ROMEX WITH IN 12" OF BOXES 6.) BOTTOM FLOORS CHECK ALL THE CONNECTS GOING INTO PANELS MUST BE SNAPPED IN. 7.) ALL RANGE CABLES TO BE NAILED WITH IN 12" OFF BOXS HAVE ELECT CONTRACTOR CHECK ALL THIS ITEMS AND RECALL.