Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
Permit Number - T01CM01209
Inspection Description - PLUMBING - YARD WTR LINE/TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2001 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection 0000*1.) MUST CERTIFY AND TEST BACKFLOW PREVENTER @ TIME OF FINAL 2.) OK TO BACKFILL TRENCH. | |
| 09/30/2001 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection 0000*1.) PVC YARDWATER FROM BLDG TO METER OK PRESSURE TEST OK 2.) OK TO BACKFILL 3.) THE SCH 40 PVC MALE ADAPTER AT THE METER IS NOT APPROVED CONNECTION BETWEEN IPS X PVC SHALL BE MADE WITH A SCH 80 NIPPLE AND JOINED WITH APPROVED SOLVENT CEMENT. | |
| 09/27/2001 | PLUMBING - YARD WTR LINE/TEST | Denied | IVRS - Inspection 0999*1.) UNABLE TO DO INSPECTION BLDG NUMBERS NOT POSTED. |