Permit: T01CM01173

Parcel: 11706219C


Addresses:

335 E 12TH ST


Inspection Status: Not ready for Inspection

Inspection History: ELECTRIC - CABLE DROP

Permit Number - T01CM01173

Inspection Description - ELECTRIC - CABLE DROP

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
12/20/2001 ELECTRIC - CABLE DROP Not ready for Inspection IVRS - Inspection 0000$
12/19/2001 ELECTRIC - CABLE DROP Not ready for Inspection IVRS - Inspection 0000*AT MAIN HOUSE 1.) NEED PERMANENT METAL ADDRESS TAG FOR SERVICE. 2.#14. TAILS TAPPED OFF OF 20 AMP. CIRCUIT 3.) 1 CIRCUIT WIRED W/14-2 RX. 4.) SPLICE 6" TAILS TO SHORT WIRES IN BOX 4 PLEASE STRIP RX CABLE IN BOX ALL THE WAY BACK TO THE ENTRY. AT REAR/STORAGE 1 CIRCUIT TO BE RATED AT 15 AMPS CHANGE PLANS NEED GROUNDING TAILS FOR SWITCHES EXTEND WIRES TO 6" MIN. NEED CRIMP SLEEVES OR OTHER APPROVED MEANS FOR SPLICING GROUND WIRES.
12/17/2001 ELECTRIC - CABLE DROP Partial Approval IVRS - Inspection 0000*
12/13/2001 ELECTRIC - CABLE DROP Denied IVRS - Inspection 0999$
11/01/2001 ELECTRIC - CABLE DROP Denied IVRS - Inspection 0999*