Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01CM01161

Parcel: 141112160

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T01CM01161

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/23/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
04/20/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1) 2ND FLOOR REAR SHEAR NOT NAILED 2) KING STUD NEEDED AT GARAGE PH22 3) ROOF PANEL LOOSE AT FRONT
04/19/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1) PANEL NOT NAILED OVER FRONT DOOR, 1 AT RIGHT (ROOF) HIP VALLEY AND ONE ON SOUTHEAST FACING HIP ROOF PLANE 2) 2ND FLOOR REAR SHEAR PANELS MISSING SOME NAILING 3) MISSING SOME CLIPS 4) STRAP AND CLIP FRONT POST AT TRUSS 5) CUT FRONT WALL TOP PLATE FROM TRUSS BEARING 6) NAIL OFF SHEARWALLS 7) STRAP AND NAIL OFF PH 22 AT GARAGE