Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/23/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/20/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1) 2ND FLOOR REAR SHEAR NOT NAILED 2) KING STUD NEEDED AT GARAGE PH22 3) ROOF PANEL LOOSE AT FRONT |
| 04/19/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1) PANEL NOT NAILED OVER FRONT DOOR, 1 AT RIGHT (ROOF) HIP VALLEY AND ONE ON SOUTHEAST FACING HIP ROOF PLANE 2) 2ND FLOOR REAR SHEAR PANELS MISSING SOME NAILING 3) MISSING SOME CLIPS 4) STRAP AND CLIP FRONT POST AT TRUSS 5) CUT FRONT WALL TOP PLATE FROM TRUSS BEARING 6) NAIL OFF SHEARWALLS 7) STRAP AND NAIL OFF PH 22 AT GARAGE |