Date Description Inspector Results Comments
06/11/2001 FRAMING Approved IVRS - Inspection 0000*
06/06/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) NAIL OFF MULTI-TRUSS BRACKET IN GARAGE 2) STRAP GARAGE TOP PLATE AT GAS AND PEX CUTS 3) NO GAS PRESSURE 4) STRAP A/C LINES BACK INTO STUD BAY IN GARAGE 5) BANG PLATE TPR LINE IN LIVING ROOM AND GARAGE WALL 6) WRENCH TIGHTEN HOLD DOWN UNDER STAIR LANDING 7) SHIM TRIMMER AND HEADER UNDER STAIR LANDING 8) STRAP STAIR LANDING HEADER 9) STRAP KITCHEN PLUMBING VENT CUT IN TOP PLATES (NOT BANG PLATES) 10) NEED STUD SHOE AT KITCHEN VENT CUT