Permit: T01CM01153

Parcel: 110101520


Addresses:

4922 E GARRISON CT

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
06/27/2001 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
06/26/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection 1) MISSING CHAIRS, CABLE DOGS NOT NAILED TO FORM P.A.S. NOT SECURE
06/25/2001 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*/ 1) HORIZONTAL REBAR LAYING ON THE GROUND, NOT SUPPORTED 2) CABLES AT GARAGE STEM AND FTG ONE EACH SIDE ARE TOUCHING THE 2X FORM, CABLES IN GARAGE FLOOR ARE LOWER THAN THE END GABLES, CABLES AT STEMS LOOK TO BE TO HIGH
06/22/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*/ 1) FITTING WIDTH AT BOTTOM TOO BE 1'-6" 2) DEPTH AT GARAGE STEM WALL NOT DEEP ENOUGH