Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/31/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
05/08/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*
05/07/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) GIRDERS BEARING EXTRA STUDS 2) OVERLAY TRUSSES CONTINOUS BEARING 3) 2-3 PLY CONNECTIONS 4) ROOF NAILING
05/03/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) MANY ROOF PANELS NOT NAILED OR HAVE NAILS SPACED GREATER THAN 6" OC AT SUPPORTED ENDS AND EDGES AND 12" IN FIELD 2) NO PLANS/PERMIT ON SITE 3) SEE 5/1/01 INSP
05/01/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/1) WALK ROOF CHECK NAIL SPACING 2) FRONT HIP 30" SPAN TOWARD TO OF HIP 3) BLOCK ALL LEDGES NOT SUPPORTED ROOF SHEATHING RUN PARALEL TO TRUSS 4) SECURE F/PLACE CHASE 5) LEAVE TRUSS SHOP DRAWINGS AND GIRDER TRUSS (TRIPLE) HOW ARE THEY ATTACHED 6) NEED PLANS AND PERMIT ON SITE
04/05/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/1. BOTTOM PLATE ATTACHMENT.