Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM01126

Parcel: 114480570

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/12/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
06/06/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) REAR PARAPET NOT SECURED MAYBE REQUIRE SHEAR 2) SAME LOCATION ROOF DECK MISSING NAILING AND BACKING AT EDGE NEXT TO PARAPET 3) GARAGE EXTENSION, HOW BIG IS EXTENSION? 22' 0" SEE TJI SPACING FOR EXTENSION 4) TIE BAY WINDOW WALLS TOGETHER WITH 2 X 4 BLOCKS OR FULL STUDS 5) 8/D1 CROSS BRACING NOT DIAGNOAL X 6) CHECK FOR 24" ON CENTER BLOCKING REAR PARAPET