Permit: T01CM01114

Parcel: 141113030


Addresses:

8452 E HODGMAN PL


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM01114

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/14/2001 FRAMING Approved IVRS - Inspection 0000*
05/11/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) SHIM STUD ADJACENT TO HOT WATER HEATER 2) NEED GAS PRESSURE FOR TEST-6 LBS AT PRESENT 3) SHIM HEADER-1ST FLOOR SOUTHEAST WINDOW AND NORTHEAST WINDOW 4) GROUND PANCAKE BOX IN STAIRWELL AND METAL BOX AJ MASTER DECK 5) REMOVE OSB FROM FLUE PIPES-2ND FLOOR NORTHWEST 6) NAIL 2 X 4 CEILING JOIST AT MASTER DECK DOOR 7) STRAP NON-CABIN TIED TOP PLATES AT MASTER SOUTHWEST CORNER AROUND PAR LAM 8) REPLACE CUT X BRACE AT EAST END AND NO MIDDLE X BRACE 9) NO BRACKETS ON STUB HIP TRUSSES