Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/18/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/PROVIDE TRUSS CALC'S
04/17/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0950*/1) POST TO BEAM CONNECTION AT ENTRY NOT INSTALLED CORRECT 2) PROVIDE BLKS UNDER OVER FRAME AT ENTRY 3) SECURE BUILT UP 2X UNDER DBL GIRDERS FACE NAIL 4) BLK UNDER GIRDER 5) PROVIDE POSITIVE CONNECTION AT BEARING STUDS 10" OC 6) DRAFT STOPS MISSSING AT COLUMNS SECURE AND BLOCK SHEAR TRANSFER WALLS 7) PROVIDE COT APPROVED TRUSS CALDS