Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/18/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000*/PROVIDE TRUSS CALC'S |
| 04/17/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0950*/1) POST TO BEAM CONNECTION AT ENTRY NOT INSTALLED CORRECT 2) PROVIDE BLKS UNDER OVER FRAME AT ENTRY 3) SECURE BUILT UP 2X UNDER DBL GIRDERS FACE NAIL 4) BLK UNDER GIRDER 5) PROVIDE POSITIVE CONNECTION AT BEARING STUDS 10" OC 6) DRAFT STOPS MISSSING AT COLUMNS SECURE AND BLOCK SHEAR TRANSFER WALLS 7) PROVIDE COT APPROVED TRUSS CALDS |