Permit: T01CM01068


Addresses:

495 N PLACITA MIRA

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/27/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) NEXT INSPECTION HAVE CARPENTER INSTALL ALL LATERAL BRACING NOTED ON YOUR TRUSS DRAWINGS
06/25/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) NEED TRUSS SHOP DRAWINGS (SEE LAST INSPECTION) YOU HAVE 3 PT BEARING TRUSSES, I NEED TO CHECK THEM 2) RETRO FIT H-D'S IN REAR ARE MANUFACTURED BY ADVANCED, ANCHORAGE WAS TOO BE 5/8" YOU HAVE SOME USING 1/2" 3) MISSED 3' OF ROOF NAIL AT LEDGER AGAINST PARAPET NEAR WATER FLUE 4) RE-NAIL TRUSS STUDS AT GARAGE BEAM BOTTOM PLATE
06/21/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) MISSING NAILING SHEAR WALLS 2) REAR PA AT BAY WINDOW NOT NAILED 3) PA AT REAR SLIDER MISSED SHEAR PANEL NEED RETRO-FIT 4) REAR PORCH POST TO BEAM CONNECTION NOT INSTALLED 5) A-BOLT BANG PLATE GARAGE BEAM WEST SIDE 6) TWO SHEAR WALLS H3 NORTH WEST CORNER MISSING PA'S 8) NEED TRUSS SHOP DRAWINGS 9) ROOF NOT NAILED BEFORE NAILING CRICKETS MAKE SURE ALL PERIMETER NAILING IS DONE ALL LEDGERS 10) NEED BETTER CONNECTION AT PORCH LEDGER