Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/27/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000*/ 1) NEXT INSPECTION HAVE CARPENTER INSTALL ALL LATERAL BRACING NOTED ON YOUR TRUSS DRAWINGS |
| 06/25/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NEED TRUSS SHOP DRAWINGS (SEE LAST INSPECTION) YOU HAVE 3 PT BEARING TRUSSES, I NEED TO CHECK THEM 2) RETRO FIT H-D'S IN REAR ARE MANUFACTURED BY ADVANCED, ANCHORAGE WAS TOO BE 5/8" YOU HAVE SOME USING 1/2" 3) MISSED 3' OF ROOF NAIL AT LEDGER AGAINST PARAPET NEAR WATER FLUE 4) RE-NAIL TRUSS STUDS AT GARAGE BEAM BOTTOM PLATE |
| 06/21/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) MISSING NAILING SHEAR WALLS 2) REAR PA AT BAY WINDOW NOT NAILED 3) PA AT REAR SLIDER MISSED SHEAR PANEL NEED RETRO-FIT 4) REAR PORCH POST TO BEAM CONNECTION NOT INSTALLED 5) A-BOLT BANG PLATE GARAGE BEAM WEST SIDE 6) TWO SHEAR WALLS H3 NORTH WEST CORNER MISSING PA'S 8) NEED TRUSS SHOP DRAWINGS 9) ROOF NOT NAILED BEFORE NAILING CRICKETS MAKE SURE ALL PERIMETER NAILING IS DONE ALL LEDGERS 10) NEED BETTER CONNECTION AT PORCH LEDGER |