Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/02/2001 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* |
| 05/18/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) SEWER LINE MUST BE 12" BELOW GRADE FROM TOP OF SOIL TO TOP OF SEWER PIPE 2) UNDER SLAB DRAIN MUST CONTINUOUSLY BEAR ON COMPACTED SOIL PRESENTLY SUSPENDED ON BLOCKS 3) KITHCEN DRAIN LINE MUST BE UNDER SLAB, PRESENTLY ABOVE FORMS 4) IF INCREASING THE FINISHED FLOOR ELEVATION THE PLUMBING MAYBE OK ONCE PROPERLY SUPPORTED 5) SHALLOW SEWER LINE, PERMITTED ONLY IF ENCASING IN CONCRETE UNDER A BLDG OR PORCH, ONCE OUTSIDE OF BLDG THEN IT MUST BE 12" BELOW GRADE PER UPC 718.3, IF LOWERING WITH WALK REVISE PLAN |