Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM01067

Parcel: 123090600


Addresses:

2619 E MABEL ST #02

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
08/02/2001 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
05/18/2001 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) SEWER LINE MUST BE 12" BELOW GRADE FROM TOP OF SOIL TO TOP OF SEWER PIPE 2) UNDER SLAB DRAIN MUST CONTINUOUSLY BEAR ON COMPACTED SOIL PRESENTLY SUSPENDED ON BLOCKS 3) KITHCEN DRAIN LINE MUST BE UNDER SLAB, PRESENTLY ABOVE FORMS 4) IF INCREASING THE FINISHED FLOOR ELEVATION THE PLUMBING MAYBE OK ONCE PROPERLY SUPPORTED 5) SHALLOW SEWER LINE, PERMITTED ONLY IF ENCASING IN CONCRETE UNDER A BLDG OR PORCH, ONCE OUTSIDE OF BLDG THEN IT MUST BE 12" BELOW GRADE PER UPC 718.3, IF LOWERING WITH WALK REVISE PLAN
05/16/2001 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0305*/ 1) SEWER LINE REQUIRES 1/4" PER FOOT POSITIVE SLOPE-SOME AREAS NEGATIVE 2) SEWER LINE MUST BE 12" BELOW GRADE TO TOP OF PIPE AT EXIT OF BUILDING 3) REVERSE FLOW AT SHOWER AND LAUNDRY DRAIN 4) MAXIMUM ALLOWABLE HORIZONTAL BENDS OF 135 DEGREE EXCEEDED WITHOUT A CLEAN OUT