Date Description Inspector Results Comments
04/27/2001 FRAMING Approved IVRS - Inspection 0000*
04/26/2001 FRAMING Denied IVRS - Inspection 0999*/1) CALAPSED FLEX DUCT AT HALL BATH 2) RA RELIEF REGISTER IN HALLWAY NOT CONNECTED TO DUCT 3) WRENCH TIGHTEN ABS AND REDHEADS 4) PLATES REQ BOLT WITHIN 12" OF CUTS AND ENDS 5) REPLACE BAD STUD IN MASTER BATH WALL 6) ANCHOR ELEC BOX IN MASTER BR WALL 7) SEVERAL FLEX DUCTS ARE BUNCHED AND KINKED COCK REQUIRES THAT FLEX DUCT BE FULLY EXTENED FOR MAX AIR FLOW