Permit: T01CM00979

Parcel: 13314227B


Addresses:

1400 N WILMOT RD


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T01CM00979

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
01/15/2002 PLUMBING - ROUGH, SOIL Approved
01/14/2002 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1.) 4" BLDG DRAIN HAS BACK PITCH MIN OF 1% PITCH. 2.) CAN NOT HAVE ANY BUSHINGS IN DRAIN.
01/09/2002 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) THIS INSPECTION IS FOR ROUGH PLBG. IN RM #156,166, 3.) OK TO BACKFILL TRENCH.
11/06/2001 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*1.) HAD MEETING WITH SUPERINTENDENT ON ACID WASTE SYSTEM.
10/31/2001 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*
07/25/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) P.O.C.OF NEW 10" BLDG. DRAIN TO EXSISTING BLDG. DRAIN IS OK 2.) THIS INSPECTION IS FOR BLDG. DRAIN IN CORRIDOR #160 ONLY 3.) OK TO BACKFILL TRENCH. 4.) NOTE: WILL REQUIRED A REVISED & APPROVED DRAWINGS ON 10" BLDG. DRAIN AND P.O.C. BEFORE FINAL INSPECTION.
07/18/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) 4" BLDG SEWER TO MAN HOLE INVERT IS OK 2.) OK TO BACKFILL TRENCH.
07/17/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) SOIL WATER TEST OK 2.) P.O.C. OF UPSTREAM 10" PVC BLDG SEWER TO MANHOLE IS OK 3.) THIS INSPECTION IS FOR 10" BLDG SEWER FROM NEW MANHOLE TO EXSISTING MANHOLE.
07/02/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) 4" BLDG SEWER IS STUBBED OUT TO 20" PAST OF CANOPY 3.) OK TO BACKFILL TRENCH.
06/26/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) SOIL WATER TEST OK 2.) BLDG SEWER HAS BEEN STUBBED 20' 3.) OK TO BACKFILL TRENCH
06/21/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1)SOIL WATER TEST OK.
2)NOTE:FLOOR DRAIN IN WASH DOWN AREA #115 WILL REQUIRE A C.O. DUE TO BRANCH LINE EXCEEDS 5'-0" FROM TRUNK LINE.3)OK TO BACKFILL TRENCH.
06/11/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1)SOIL WATER TEST OK.2)ALL
CORRECTIONS HAVE BEEN MADE.3)OK TO BACKFILL
TRENCH.4)NOTE:WILL REQUIRE A REVISED AND APPROVED DRAWING PRIOR TO FINAL.
06/08/2001 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1)MUST PROVIDE 10' HEAD FOR WATER TEST.2)WILL REQUIRE A FLOOR C.O. WHERE BUILDNG DRAIN EXCEEDS 135'.