Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/17/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 07/16/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0950*/ 1) OUTSIDE HOSE BIBS REQUIRE ANTI-SIPHON VALVE 2) LEAK ON WATER SERVICE LINE OUTSIDE 3) GAS BOND NOT PROPERLY INSTALLED-CANNOT BE INSTALLED ON REMOVABLE CAP 4) SOIL MUST BE GRADED AWAY FROM HOUSE AT 2 PERCENT FOR 5' 5) A/C DISCONNECT MUST HAVE 30 X 30 WORK AREA IN FRONT OF DISCONNECT OBSTRUCTION BY A/C-NEED FUSES |