Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T01CM00932
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/16/2001 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
| 03/14/2001 | BUILDING - FINAL | Partial Approval | IVRS - Inspection 0000* | |
| 03/05/2001 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/1. EXPOSE FOOTING IN THREE PLACES, ONE ON EACH SIDE OF ADDITION TO A DEPTH OF 14" BELOW GRADE. 2. EXPOSE RAFTER AND LEDGER CONNECTIONS ON EACH NORTH AND SOUTH WALL OF ADDITION. 3. ELECTRIC OUTLETS REQUIRED WITHIN 6 FEET OF DOORWAY AND EVERY 12 FEET THERE AFTER. 4. PROVIDE PROOF OF HEADER SIZES FOR WINDOWS. 5. OPEN ALL ELECTRIC OUTLET BOXES IN ADDN FOR INSPECTION. 6. OPEN ELECTRIC SUB PANEL FOR INSPECTION. 7. OPEN KNOCK OUT IN SUB PANEL. 8. SMOKE DETECTORS REQUIRED IN EACH BEDROOM. 9. PERMANENTLY INSTALLED SECURITY BARS NOT ALLOWED IN BEDROOMS. 10. INTERIOR ELECTRIC SERVICE PANEL NOT ALLOWED OUTSIDE. |