Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/05/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/03/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/1. PORCH JOIST HANGERS NOT NAILED. 2. REPLACE RED HEADS THAT BROKE THROUGH SLAB SIDE (WILL CHECK AT INT.) |
| 04/02/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. ONE ROOF PANEL NOT NAILED SOUTH PLANE. 2. JACK TRUSS BRACKED NOT NAILED AT FRONT MIDDLE. 3. MISSING HEADER STRAPS ON WEST WINDOW. |
| 03/29/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. ROOF PANELS NOT NAILED. 2. MISSING: A. STUD CLIPS. B. HEADER STRAPS. C. COLUMN ANCHORS. 3. MOST REDHEADS ARE LOOSE. 4. PATIO ROOF LEDGER MUST BE PROPERLY RE-INSTALLED. |