Inspection Status: Approved
Inspection History: STUCCO MESH
Permit Number - T01CM00916
Inspection Description - STUCCO MESH
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/25/2001 | STUCCO MESH | Approved | IVRS - Inspection 0000* | |
05/24/2001 | STUCCO MESH | Denied | IVRS - Inspection 0999*/ 1) I CANNOT APPROVE STUCCO LATH PRIOR TO APPROVING FOUNDATION, FRAME AND EXTERIOR CLIP INSPECTIONS 2) IF FOUNDATION AND FOOTINGS HAVE NOT BEEN APPROVED EXPOSE FOOTINGS ALL AROUND STRUCTURE TO 12" BELOW GRADE 3) DOORS AND WINDOWS MUST HAVE A MINIMUM OF DOUBLE 2 X 4 HEADERS WITH 1/2" SHIM AND HEADERS MUST BEAR ON TRIMMERS NAILED TO KING STUDS-SILLS MUST BEAR ON CRIPPLE STUDS 4) EXTERIOR SHEATHING MUST BE NAILED TO STUDS AT 8" ENDS AND EDGES 12" IN FIELD 5) BUILDING APPREARS TO NOT HAVE FOOTING HAVE PLANS ANNOTATED TO NOT REQUIRE FOOTINGS OR TO SPECIFY REQUIREMENT 6) ELECTRIC AND PLUMBING NOT READY | |
05/23/2001 | STUCCO MESH | Denied | IVRS - Inspection 0925*/ 1) NO PLAN/PERMIT ON SITE, PROPERTY LOCKED, NO ACCESS |