Permit: T01CM00897

Parcel: 133554400

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/09/2001 FRAMING Approved IVRS - Inspection 0000*
04/06/2001 FRAMING Denied IVRS - Inspection 0925*/NO PLANS AT SITE.
04/04/2001 FRAMING Denied 1. NEED SPECIAL INSP FOR H.D. INSTALLED FOR 1025 APPROVAL. 2. MISSING INTERIOR HD'S.
04/02/2001 FRAMING Denied IVRS - Inspection 0999*/1. HAS 26 HANGERS AT GIRDERS REQUIRE DIAGONAL NAILING WITH MIN. 12D SINKERS NOT TECO NAILS (PER SIMPSON). 2. NO TEST ON WATER SYSTEM. 3. HOLDOWNS MISSING AT INTERIOR SHEARWALLS. 4. HEADERS IN BEARING WALLS MUST BEAR ON TRIMMERS. 5. MECHANICAL PLAN CALLS FOR ADDITIONAL AIR REGISTER IN MASTER BR.