Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/09/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/06/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0925*/NO PLANS AT SITE. |
| 04/04/2001 |
FRAMING |
|
Denied |
1. NEED SPECIAL INSP FOR H.D. INSTALLED FOR 1025 APPROVAL. 2. MISSING INTERIOR HD'S. |
| 04/02/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. HAS 26 HANGERS AT GIRDERS REQUIRE DIAGONAL NAILING WITH MIN. 12D SINKERS NOT TECO NAILS (PER SIMPSON). 2. NO TEST ON WATER SYSTEM. 3. HOLDOWNS MISSING AT INTERIOR SHEARWALLS. 4. HEADERS IN BEARING WALLS MUST BEAR ON TRIMMERS. 5. MECHANICAL PLAN CALLS FOR ADDITIONAL AIR REGISTER IN MASTER BR. |