Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/12/2002 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 07/26/2001 |
ROOF NAILING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) PORCH LEDGER REQUIRES 5/8" X 6" ANCHOR BOLTS AT 6" ON CENTER, SEE PAGE 11 WEST ELEVATION 8/6 |
| 07/02/2001 |
ROOF NAILING |
|
Partial Approval |
|
| 06/26/2001 |
ROOF NAILING |
|
Partial Approval |
|
| 06/25/2001 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) GUEST HOUSE REQUIRES 2 X 12 RAFTERS AT 12" ON CENTER INSTALLED AT 16" ON CENTER 2 X 10" 2) GUEST HOUSE IS NOT BUILT PER PLAN, REVISE PLAN TO AS BUILT AND HAVE APPROVED BY CITY OF TUCSON OR BUILD TO PLAN 2) HOUSE ADDITION ROOF OK FRONT AND REAR PORCHES AND GUEST HOUSE NOT READY 3) OK-TO DRY IN HOUSE ADDITION ROOF ONLY |