Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/23/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/10/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
HIP HANGERS NOT INSTALLED OR NAILED ABOVE ENTRY, OK TO DRY IN CHECK AT INTERMEDIATE |
| 04/09/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/NOTHING CORRECTED FROM PREVIOUS LIST OF 9 ITEMS AND NEED POST UNDR TRUSS GIRDER. |
| 04/05/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. INSTALL ALTERNATE HOLDOWN AT FRONT WINDOW. 2. NAIL OFF HEADER STRAPS ON RIGHT SIDE WINDOW HEADERS. 3. DIAGONAL BRACING SHOULD HAVE TWO NAILS AT TOP AND BOTTOM. 4. PATIO WINDOW MISSING A HEADER STRAP. 5. OSB NOT NAILED AT PATIO. 6. POST/GIRDER BRACKET MISSING ON PATIO. 7. MISSING HEADER STRAPS ON FRONT ARCHWAY. 8. STRAP TOP PLATES AT 2 X 4/2 X 6 WALL INTERSECTION ON LEFT SIDE. 9. CORRECT AND SECURE PONYWALL WITH SHORT STUDS, ABOVE AND TO THE LEFT OF FRONT DOOR. |