Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T01CM00861
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/13/2001 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* WATER TEST RISERS ONLY. OK TO BACKFILL | |
03/12/2001 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999* 1) NOT INSTALLED PER PLAN 2) ALL PIPING TO BE ON A FIRM BED-NO BRIDGING 3) HORIZONTAL VENTING BELOW FLOOD LEVEL NOT ALLOWED IF WITH IN TRAP ARM DISTANCE FROM PARTITIONS |