Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM00858
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/08/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
08/06/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) PROVIDE STRAPING AT GARAGE OPENING SEE DT1 14 2) GROUND NOT CONNECTED AT ELECTRIC BOX AT GARAGE 4) MISSING NAILS AT HIP TRUSS HANGER AT GARAGE 5) REMOVE SCREEN FROM DRY VENT EXIT 6) PROTECT PEX AT MASTER BATHROOM 7) FLUE PIPE FOR FIREPLACE NOT INSTALLED |