Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/08/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 08/06/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE STRAPING AT GARAGE OPENING SEE DT1 14 2) GROUND NOT CONNECTED AT ELECTRIC BOX AT GARAGE 4) MISSING NAILS AT HIP TRUSS HANGER AT GARAGE 5) REMOVE SCREEN FROM DRY VENT EXIT 6) PROTECT PEX AT MASTER BATHROOM 7) FLUE PIPE FOR FIREPLACE NOT INSTALLED |