Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 04/16/2002 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) GAS PRESSURE TEST IS OK 4.) OK FOR DRYWALL. |
| 04/10/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) CAN NOT USE GALVANIZED 90 AS DRAINAGE FITTINGS. SEE SECTION: 701.2 94 UPC 2.) MUST USE FIG 1 TAP TEE FOR BACK TO SAN CROSS THE BARREL MUST BE 2 PIPES SIZES LARGER THAN TRAP ARMS SEE SECTION: 706:2 94 UPC. 3.) MUST PROVIDE HANGER ON HORIZONTAL 2" VENT. 4.) MUST USE REQUIRED TEST GAUGE WITH 1/10 INCREMENTS SEE SECTION: 712.4.1. 94 UPC 5.) RE TEST WASTE & VENT SYSTEM. 6.) MUST GET REVISION ON GAS LINE THAT APPEARS TO BE ADDED ON APPROVED DRAWING. |